CoreImage - WaaS SCCM Reports


Introduction

To access WaaS SCCM Reports, first ensure you are connected to the Michigan Medicine network or VPN and then follow this link to WaaS Reports.

 WaaS SCCM Reports

Instructions

Navigating WaaS Reports

Review a Specific Term ID

This report shows the status of a specific term ID (ex: MSW00371, MSW00373).

Review Devices in Collections

This report shows the number of machines in each collection.

Compliance-All Report

This report gives the upgrade status of all devices.

  • Select the Compliance All report on page three of the Feature Update report for the total number of devices and a complete list of devices.

    • To search for a specific device, enter the term ID into the search box and select Find. 

compliance all

Review Collections Based on Dates

This report shows which devices are updating on a specific date.

  • Starting on page 4 of the Feature Update report, select a date to see the total number of devices upgrading and which specific devices are scheduled to update.
    • The devices listed here are not excluded and are ready for deployment.

upgrade dates

 

List of all Unsupported Hardware

This report gives the list of unsupported hardware models as well as the number (Member Count) in the environment. 

  • To download a report for further review, review Exporting a Report to a CSV
  • All unsupported hardware will be remediated and replaced.

 

WaaS Exclusions

This report shows which devices are excluded from Windows 11. 

  • The exclusion reports start on page seven of the Feature Update report.
  • Select any collection to see a complete list of devices.

List of All Excluded Devices

This report gives the number of devices for specific exclusions and/or the total number of exclusions.

Additional Exclusions Information:

  • During packaged application testing, multiple applications were not compatible with Windows 11​ (WaaS - Application Exclusions).
  • Exclusions can be for the following buckets:
    • Applications (Mcard 1.0, Pedz PES 2.1.1.0, Codemeter 7.21a)
    • Ad Hoc Departments (Anesthesiology, Radiation Oncology, Pharmacy)
    • Other (unsupported hardware, 60+ profiles, insufficient disk space, offline failure exclusions, inactive AD)
  • A device can be a member of an exclusion (which are buckets for either application, ad hoc, or hardware-excluded devices) and also have another type of "blocking" category (like disk space = failed preassessment).  
    • For example, of the total 8357 currently excluded, 6398 are in a "Ready for Deployment State" and would be candidates for upgrade if the exclusions were lifted.
  • Once an application is compatible with Windows 11, the devices that have the application installed will be updated
  • Flex devices and other department areas are excluded​.
  • Users can update by navigating to Software Center 
  • Unsupported hardware will be remediated and replaced

Scheduling Exclusions for the WaaS Upgrades

When the application becomes compatible (via fix or upgrade) with Windows 11 and/or the department is ready to receive the upgrade, EDEM creates a schedule to keep all the devices from updating at one time

 

Common Waas Report Terms

  • Scrutineering refers to the hardware check
  • Preassessment refers to disk space check, AD activity, device reporting, etc.
  • If a space is blank, the device hasn't yet reported status for the PreStage execution (but has passed scrutineering and preassessment)
  • An exclusion refers to when a device(s) is kept from upgrading via the WaaS IPU process
  • The Member Count column refers to the number of devices
  • 1900 in the date field means no date set or NULL. 

 

Exporting a Report to a CSV
  • To download/save a report for further review, open the report and select Save.
    • Select CSV (comma delimited) from the menu.

    export waas report